POD14B is a dual AES/EBU analog to digital audio converter. This unit comes ready for use in 75 Ohm or 110 Ohm installations. POD14B can generate digital audio signals at sampling rates of 32, 44.1, 48, 96 and 192 kHz using its internal oscillator. Alternatively the sampling rate of the digital output signals may be referenced to an external source.Front panel controls and tallies include a power switch with LED tally, a momentary step switch and LED indicators to cycle through the internally generated sample rates from 32 to 192 kHz. Two LEDs indicate whether the external or internal reference is used. The external reference signal has precedence over the internally generated reference signal. As soon as an external reference signal is detected POD14B will automatically switch to it. Coarse gain controls for input 1 are also available on the front panel.Connections to the POD14B are made on the rear panel. Input 1 accepts unbalanced analog signals via standard RCA connectors. Input 2 accepts balanced analog signals via 3-pin Phoenix pluggable connectors. Connections to the digital reference may be made by either 75 Ohm BNC or 110 Ohm Phoenix 3-pin pluggable connectors. Both the 75 Ohm and 110 Ohm connections of each output may be used in parallel. Fine level trim controls for the analog input signal are located adjacent to the corresponding input connectors. The AC power receptacle and fuse are also located on the rear panel.
dual AES/EBU analog to digital audio convertercomes ready for use in 75 Ohm or 110 Ohm installations
generates digital audio signals at sampling rates of 32, 44.1, 48, 96 and 192 kHz using its internal oscillator
sampling rate of the digital output signals may be referenced to an external source
Front panel controls and tallies: momentary step switch and LED indicators to select sample rates from 32 to 192 kHz
external or internal reference LED indicators
external sampling rate reference signal has precedence
Connections are made on the rear panel
Input 1 accepts unbalanced analog signals via standard RCA connectors.
Input 2 accepts balanced analog signals via 3-pin Phoenix pluggable connectors.
Both the 75 Ohm and 110 Ohm connections of each output may be used in parallel.
Fine level trim controls for the analog input signal are located adjacent to the corresponding input connectors.
The AC power receptacle and fuse are also located on the rear panel.
DIGITAL REFERENCE INPUT
Input Impedance: 75 Ohm or 110 Ohm
Input Level: 0.2-7 Vpp
Sampling Frequency Range: 32kHz to 192kHz
ANALOG AUDIO INPUT
Converter 1:
Input Impedance: 47 kOhm unbalanced
Maximum Input: +14dB
Frequency Response: +0.01/-0.26dB, 20Hz – 20kHz
Converter 2:
Input 2 Impedance: 24 kOhm balanced
Maximum Input: +24dBu
Frequency Response: ± 0.1dB, 20Hz - 20kHz
DIGITAL AUDIO OUTPUT
Resolution: 24 bits
Output Standard: AES/EBU 75 Ohm unbalanced and 110 Ohm balanced
External Sampling Frequency: 32kHz to 192kHz
Internal Sampling Frequency: Selectable 32, 44.1, 48, 96 and 192kHz
Jitter: less than 5ns
Level: 1V p-p terminated for 75 Ohm or3 V p-p terminated for 110 Ohm
Noise: better than -110 dBFS, 20Hz to 20kHz Typical unweighted
Total Harmonic Distortion + Noise: better than 0.02%
GENERAL
Power Requirements: 100-240 VAC, 50-60Hz
Dimensions: 8.69 in. wide x 1.73 in. high x 7.0 in. deep (221mm x 44mm x 178 mm)
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Estimate shipping
Refund Policy
If you are not satisfied with your product and wish to return it, please contactsales@ward-beck.com for a Return Merchandise Authorization (RMA) number. We generally charge a 25% restocking fee.
You may also like
Recently viewed
Worldwide delivery
We serve audio and broadcast professionals around the globe.
Satisfied or refunded
If you are not satisfied with your purchase, take advantage of our refund policy.
Top-notch support
Our expert team is ready to support your needs, no matter how unique or custom.
Secure payments
You can rest assured that all payments are handled with PCI compliance.